Schneider Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, <=400V, 65A, 230V AC 50/60Hz Coil, Screw Clamp terminals
Description
- New modern look & feel of all machines
- Easier to install and operate with multi-standard screws
- Improved fire resistance with IEC 60335-1(Clause 30.2) certificate by authorised agency
- Anti-flammable refrigerants with IEC/EN/UL 60335-2-40 (Annexe JJ) certificate by an authorised agency
- Digital customer experience for technical documents
(1)
Minimum electrical clearance
LC1 |
D40A…D65A |
|
---|---|---|
a |
|
55 |
b1 |
with LA4 D●2 |
– |
with LA4 DB3 or LAD 4BB3 |
136 |
|
with LA4 DF, DT |
157 |
|
with LA4 DM, DW, DL |
166 |
|
c |
without cover or add-on blocks |
118 |
with cover, without add-on blocks |
120 |
|
c1 |
with LAD N (1 contact) |
– |
with LAD N or C (2 or 4 contacts) |
150 |
|
c2 |
with LA6 DK10, LAD 6DK |
163 |
c3 |
with LAD T, R, S |
171 |
with LAD T, R, S and sealing cover |
175 |
Environmental Data Explained
How We Assess Product Sustainability
Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, <=400V, 65A, 230V AC 50/60Hz coil, screw clamp terminals
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 65A/440V AC-3/3e (30kW@400V). It provides a 230V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, and control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
EAN Code: 3389119409025
- New modern look & feel of all machines
- Designed to meet the requirements of industrial and HVAC applications
- Easier to install and operate with multi-standard screws
- With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries
- Digital customer experience for technical documents
SPECIFICATIONS
Range | TeSys TeSys Deca |
---|---|
Range of product | TeSys Deca |
Product or component type | Contactor |
Device short name | LC1D |
Contactor application | Resistive load Motor control |
Utilisation category | AC-4 AC-1 AC-3 AC-3e |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
[Ie] rated operational current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 65 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230 V AC 50/60 Hz |
Motor power kW | 11 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 220…230 V AC 50/60 Hz (AC-3) 30 kW at 380…400 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660…690 V AC 50/60 Hz (AC-3) 18.5 kW at 220…230 V AC 50/60 Hz (AC-3e) 30 kW at 380…400 V AC 50/60 Hz (AC-3e) 37 kW at 500 V AC 50/60 Hz (AC-3e) 37 kW at 660…690 V AC 50/60 Hz (AC-3e) |
---|---|
Motor power hp | 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors 5 hp at 115 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit 80 A (at 60 °C) for power circuit |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 |
Rated breaking capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 640 A 40 °C – 10 s for power circuit 900 A 40 °C – 1 s for power circuit 110 A 40 °C – 10 min for power circuit 260 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit 120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit |
Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for the power circuit 125 A gG at <= 690 V coordination type 2 for the power circuit |
Average impedance | 1.5 mOhm – Ith 80 A 50 Hz for power circuit |
Power dissipation per pole | 9.6 W AC-1 6.3 W AC-3 6.3 W AC-3e |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability | 6 Mcycles |
Electrical durability | 1.4 Mcycles 80 A AC-1 at Ue <= 440 V 1.45 Mcycles 65 A AC-3 at Ue <= 440 V 1.45 Mcycles 65 A AC-3e at Ue <= 440 V |
Control circuit type | AC at 50/60 Hz standard |
Coil technology | Without a built-in suppressor module |
Control circuit voltage limits | 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz 1…1.1 Uc (60…70 °C):operational AC 50/60 Hz |
Inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 °C) 160 VA 50 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 4…5 W at 50/60 Hz |
Operating time | 4…19 ms opening 12…26 ms closing |
Maximum operating rate | 3600 cyc/h at 60 °C |
Connections – terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…35 mm² – cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1…25 mm² – cable stiffness: solid without cable end |
Tightening torque | Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver Philips No 2 Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2 Power circuit: 2.5 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2 |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
Signalling circuit frequency | 25…400 Hz |
Minimum switching voltage | 17 V for signalling circuit |
Minimum switching current | 5 mA for signalling circuit |
Insulation resistance | > 10 MOhm for signalling circuit |
Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
Mounting support | Rail Plate |
Standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14 UL 60947-4-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2 |
---|---|
Product certifications | CCC UL CB Scheme CSA CE UKCA Marine EAC |
IP degree of protection | IP20 front face conforming to IEC 60529 |
Protective treatment | TH conforming to IEC 60068-2-30 |
Climatic withstand | conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
Permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating |
Operating altitude | 0…3000 m |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Vibrations contactor open (2 Gn, 5…300 Hz) Vibrations contactor closed (4 Gn, 5…300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms) |
Height | 122 mm |
Width | 55 mm |
Depth | 120 mm |
Net weight | 0.86 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 6.000 cm |
Package 1 Width | 13.500 cm |
Package 1 Length | 15.000 cm |
Package 1 Weight | 925.000 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 10 |
Package 2 Height | 15.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 9.732 kg |
Unit Type of Package 3 | S02 |
Number of Units in Package 3 | 10 |
Package 3 Height | 15.000 cm |
Package 3 Width | 30.000 cm |
Package 3 Length | 40.000 cm |
Package 3 Weight | 9.655 kg |
Warranty | 18 months |
---|
Visit our website to: Request for Quote Form – Emobella Engineering
Weight | 0.86 kg |
---|---|
Dimensions | 12.0 × 5.50 × 12.20 cm |
Be the first to review “Schneider Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, <=400V, 65A, 230V AC 50/60Hz Coil, Screw Clamp terminals”
Shipping policy
At our Company, we understand the importance of timely delivery. We offer a variety of shipping options to suit your needs, including standard, expedited, and express shipping. Our dedicated team works diligently to process and dispatch your orders promptly, aiming to deliver them to your doorstep within the estimated timeframe.
We strive to provide fast and reliable shipping to our customers. Here’s everything you need to know about our shipping process:
- Dispatch: Within 24 Hours
- Free shipping across all products on a minimum purchase of $99.
- International delivery time 5 to 7 business days
- Cash on delivery might be available
- Easy 30 days returns and exchanges
Please note that delivery times are estimates and may vary depending on factors such as product availability, destination, and carrier delay
Returns policy
We want you to be completely satisfied with your purchase from our website. If for any reason you are not entirely happy with your order, we’re here to help. Certain exclusions and conditions may apply, so we encourage you to review our detailed return policy for more information. Rest assured, our goal is to ensure your complete satisfaction with every purchase you make from our website
- Returned items must be unused, undamaged, and in the same condition as received.
- Original tags, labels, and packaging must be intact and included with the returned item.
- Proof of purchase, such as your order confirmation or receipt, is required for all returns.
Reviews
There are no reviews yet.