TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 80A/1000V AC-3/AC-3e (37kW@400V). It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach).
- Long durability with high operating rate
- Reliable performance under high environment
- Green Premium product
- Multi standards certified makes it possible to wide application
- Easy installation and maintenance with compact design
Main
| Range |
TeSys |
| Range of product |
TeSys Deca |
| Product or component type |
Contactor |
| Device short name |
LC1D |
| Contactor application |
Motor control
Resistive load |
| Utilisation category |
AC-3
AC-3e
AC-4
AC-1 |
| Poles description |
3P |
| [Ue] rated operational voltage |
Power circuit: <= 300 V DC 25…400 Hz
Power circuit: <= 690 V AC |
| [Ie] rated operational current |
125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage |
220 V AC 50/60 Hz |
Complementary
| Motor power kW |
22 kW at 220…230 V AC 50/60 Hz (AC-3)
37 kW at 380…400 V AC 50/60 Hz (AC-3)
45 kW at 415…440 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660…690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
22 kW at 220…230 V AC 50/60 Hz (AC-3e)
37 kW at 380…400 V AC 50/60 Hz (AC-3e)
45 kW at 415…440 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 660…690 V AC 50/60 Hz (AC-3e) |
| Motor power hp |
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
30 hp at 230/240 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code |
LC1D |
| Pole contact composition |
3 NO |
| Protective cover |
With |
| [Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuit |
| Irms rated making capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity |
1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current |
640 A 40 °C – 10 s for power circuit
990 A 40 °C – 1 s for power circuit
135 A 40 °C – 10 min for power circuit
320 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit |
| Associated fuse rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance |
0.8 mOhm – Ith 125 A 50 Hz for power circuit |
| Power dissipation per pole |
5.1 W AC-3
12.5 W AC-1
5.1 W AC-3e |
| [Ui] rated insulation voltage |
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified |
| Overvoltage category |
III |
| Pollution degree |
3 |
| [Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947 |
| Safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability |
4 Mcycles |
| Electrical durability |
0.8 Mcycles 125 A AC-1 at Ue <= 440 V
1.5 Mcycles 80 A AC-3 at Ue <= 440 V
1.5 Mcycles 80 A AC-3e at Ue <= 440 V |
| Control circuit type |
AC at 50/60 Hz standard |
| Coil technology |
Without built-in suppressor module |
| Control circuit voltage limits |
0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz |
| Inrush power in VA |
245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA |
26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation |
6…10 W at 50/60 Hz |
| Operating time |
20…35 ms closing
6…20 ms opening |
| Maximum operating rate |
3600 cyc/h at 60 °C |
| Connections – terminals |
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end |
| Tightening torque |
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
| Auxiliary contact composition |
1 NO + 1 NC |
| Auxiliary contacts type |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency |
25…400 Hz |
| Minimum switching voltage |
17 V for signalling circuit |
| Minimum switching current |
5 mA for signalling circuit |
| Insulation resistance |
> 10 MOhm for signalling circuit |
| Non-overlap time |
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact |
| Mounting support |
Plate
Rail |
Environment
| Standards |
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2 |
| Product certifications |
CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC |
| IP degree of protection |
IP20 front face conforming to IEC 60529 |
| Protective treatment |
TH conforming to IEC 60068-2-30 |
| Climatic withstand |
conforming to IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device |
-40…60 °C
60…70 °C with derating |
| Operating altitude |
0…3000 m |
| Fire resistance |
850 °C conforming to IEC 60695-2-1 |
| Flame retardance |
V1 conforming to UL 94 |
| Mechanical robustness |
Vibrations contactor open (2 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms) |
| Height |
127 mm |
| Width |
85 mm |
| Depth |
130 mm |
| Net weight |
1.59 kg |
Packing Units
| Unit Type of Package 1 |
PCE |
| Number of Units in Package 1 |
1 |
| Package 1 Height |
14.000 cm |
| Package 1 Width |
13.500 cm |
| Package 1 Length |
10.000 cm |
| Package 1 Weight |
1.546 kg |
| Unit Type of Package 2 |
S02 |
| Number of Units in Package 2 |
5 |
| Package 2 Height |
15.000 cm |
| Package 2 Width |
30.000 cm |
| Package 2 Length |
40.000 cm |
| Package 2 Weight |
8.085 kg |
| Unit Type of Package 3 |
P06 |
| Number of Units in Package 3 |
80 |
| Package 3 Height |
75.000 cm |
| Package 3 Width |
60.000 cm |
| Package 3 Length |
80.000 cm |
| Package 3 Weight |
133.300 kg |
Contractual warranty
| Warranty |
18 months |
Shipping policy
At our Company, we understand the importance of timely delivery. We offer a variety of shipping options to suit your needs, including standard, expedited, and express shipping. Our dedicated team works diligently to process and dispatch your orders promptly, aiming to deliver them to your doorstep within the estimated timeframe.
We strive to provide fast and reliable shipping to our customers. Here’s everything you need to know about our shipping process:
- Dispatch: Within 24 Hours
- Free shipping across all products on a minimum purchase of $99.
- International delivery time 5 to 7 business days
- Cash on delivery might be available
- Easy 30 days returns and exchanges
Please note that delivery times are estimates and may vary depending on factors such as product availability, destination, and carrier delay
Returns policy
We want you to be completely satisfied with your purchase from our website. If for any reason you are not entirely happy with your order, we’re here to help. Certain exclusions and conditions may apply, so we encourage you to review our detailed return policy for more information. Rest assured, our goal is to ensure your complete satisfaction with every purchase you make from our website
- Returned items must be unused, undamaged, and in the same condition as received.
- Original tags, labels, and packaging must be intact and included with the returned item.
- Proof of purchase, such as your order confirmation or receipt, is required for all returns.
Reviews
There are no reviews yet.